Medical polymers

Biodegradable medical polymers meet international quality standards for use in medicine and pharma. We help you choose the polymer with the properties your task requires.

Translucent ivory polylactide pellets in a shallow glass dish.
Biodegradable polymers

Polymers for medical devices and drug formulations.

Biodegradable polymers are high-molecular-weight compounds used to make temporary implantable medical devices. Once the device has done its job, the material degrades in the body into safe by-products.

Stacked frosted polymer films with one sheet curved upward.
Material selection

The three parameters that define polymer properties.

Translucent ivory polylactide pellets in a shallow glass dish.

Composition

Monomers define the polymer type and its behavior in the body.

  • L-lactide
  • DL-lactide
  • glycolide
  • ɛ-caprolactone
  • trimethylene carbonate
Ivory PLGA granules in a sample vial and glass dish.

Molecular weight

From 1,000 to 500,000 Da (1–500 kDa). It sets mechanical strength and degradation time: from low-molecular grades for drug formulations to high-molecular grades for implants.

Three unlabelled polymer sample vials beside a film strip and filament.

End groups

They affect hydrolysis rate and the release kinetics of the active substance.

  • hydroxyl
  • carboxyl
  • ester
  • functional

Generated material studies illustrate product forms; specifications are listed below.

Catalog

Five polymer families.

Material images are generated studies. Consult the tables for grade specifications.

We offer a wide range of medical polymers based on cyclic esters, with different compositions, molecular weights (1 to 500 kDa) and end groups. Full specifications of each material (composition, degradation time, temperatures, mechanics and fields of application) are below.

Polylactide (PLLA, PDLLA)

PLLA / P(DL)LA

A biodegradable, biocompatible, thermoplastic aliphatic polyester whose monomer is the cyclic dimer of lactic acid (L- or D,L-lactide).

The feedstock for lactic acid production is annually renewable resources such as corn and sugar cane. The properties and supramolecular structure of polylactide vary over a wide range with the content of L- and D-form lactic acid units in the polymer.

Vascular implantsOrthopedic trauma devicesAesthetic medicine productsExtended-release drug formulationsRegenerative medicine
Translucent ivory polylactide pellets in a shallow glass dish.
Polylactide chain compositionMonomer shares by grade; not a molecular sequence.

Scroll horizontally to explore the chart

100/0
50/50
70/30
0/100
0255075100
  • L units
  • D units
Polylactide chain composition (%)
GradeL units / D units
100/0100/0
50/5050/50
70/3070/30
0/1000/100
Key specifications of PLLA / P(DL)LA
L/D unit ratio100/0, 50/50, 70/30, 0/100
Degradation time6 months to 5 years
Glass transition temperature45–60 °C
Melting temperature150–200 °C
Young's modulus1.5–4 GPa
Tensile strength40–60 MPa
Elongation at break1–10%

Polyglycolide (PGA) and poly(glycolide-co-L-lactide) (PGLA)

PGA / PGLA

Polyglycolide (PGA) and poly(glycolide-co-L-lactide) (PGLA) offer high mechanical properties and an adjustable degradation time.

They are widely used to produce fibers, sutures and various medical devices for surgery.

Surgical suturesFibers and meshes
Coiled white braided PGA and PGLA suture fibers beside a clear monofilament.
PGA / PGLA chain compositionMonomer shares by grade; not a molecular sequence.

Scroll horizontally to explore the chart

100/0
90/10
15/85
0255075100
  • Glycolide
  • L-lactide
PGA / PGLA chain composition (%)
GradeGlycolide / L-lactide
100/0100/0
90/1090/10
15/8515/85
Key specifications of PGA / PGLA
Glycolide / L-lactide ratio100/0, 90/10, 15/85
Degradation time2 to 12 months
Glass transition temperature35–50 °C
Melting temperature180–230 °C
Young's modulus3–7 GPa
Tensile strength50–100 MPa
Elongation at break1–10%

Poly(D,L-lactide-co-glycolide) (PLGA)

PLGA / P(DL)GA

Statistical copolymers of D,L-lactide with glycolide (PLGA) are characterized by good solubility and a short degradation time.

They are mainly used to create nano- and micro-particulate drug formulations and extended-release coatings. The release kinetics of the active agent can be tuned by changing the composition and molecular weight of the polymer.

Extended-release and targeted drug formulationsNanoparticles and microparticlesDrug coatings for implantsRegenerative medicine
Ivory PLGA granules in a sample vial and glass dish.
PLGA chain compositionMonomer shares by grade; not a molecular sequence.

Scroll horizontally to explore the chart

85/15
75/25
50/50
0255075100
  • D,L-lactide
  • Glycolide
PLGA chain composition (%)
GradeD,L-lactide / Glycolide
85/1585/15
75/2575/25
50/5050/50
Key specifications of PLGA / P(DL)GA
D,L-lactide / glycolide ratio85/15, 75/25, 50/50
Degradation time1 to 6 months
Glass transition temperature40–50 °C
Young's modulus1–2 GPa
Tensile strength30–40 MPa
Elongation at break1–10%

Poly(ɛ-caprolactone) (PCL)

PCL

Poly(ɛ-caprolactone) is a semi-crystalline biodegradable polymer produced by polymerization of ɛ-caprolactone.

It has a low melting temperature and high elongation at break.

Vascular implantsFibers and surgical suturesAesthetic medicine productsExtended-release drugsRegenerative medicine
Pearlescent PCL pellets beside a coil of translucent filament.
PCL chain compositionMonomer shares by grade; not a molecular sequence.

Scroll horizontally to explore the chart

100/0
0255075100
  • ɛ-caprolactone
  • Other units
PCL chain composition (%)
Gradeɛ-caprolactone / Other units
100/0100/0
Key specifications of PCL
Degradation time3 to 4 years
Glass transition temperature−60 °C
Melting temperature60–65 °C
Young's modulus0.2–0.4 GPa
Tensile strength20–40 MPa
Elongation at break300–1000%

Poly(L-lactide-co-ɛ-caprolactone) (PLCL)

PLCL

Copolymers of L-lactide with ɛ-caprolactone offer higher elongation at break than polylactide and degrade faster.

The degradation time and mechanical properties are set by the L-lactide / ɛ-caprolactone ratio in the copolymer.

Vascular implantsOrthopedic trauma devicesAesthetic medicine productsRegenerative medicine
Flexible translucent PLCL ribbon loop beside clear pellets.
PLCL chain compositionMonomer shares by grade; not a molecular sequence.

Scroll horizontally to explore the chart

90/10
75/25
50/50
0255075100
  • L-lactide
  • ɛ-caprolactone
PLCL chain composition (%)
GradeL-lactide / ɛ-caprolactone
90/1090/10
75/2575/25
50/5050/50
Key specifications of PLCL
L-lactide / ɛ-caprolactone ratio90/10, 75/25, 50/50
Degradation time3 to 18 months
Glass transition temperature20 to 50 °C
Melting temperature120 to 180 °C
Young's modulus0.3–1.5 GPa
Tensile strength20–50 MPa
Elongation at break30–1000%
Comparison

All grades in one table.

Comparative specifications of Resorbio biodegradable medical polymers
ParameterPolylactidePGA / PGLAPLGAPCLPLCL
Monomer ratio L/D 100/0, 50/50, 70/30, 0/100glycolide/L-lactide 100/0, 90/10, 15/85D,L-lactide/glycolide 85/15, 75/25, 50/50—L-lactide/ɛ-CL 90/10, 75/25, 50/50
Degradation time 6 months to 5 years2–12 months1–6 months3–4 years3–18 months
Glass transition temperature 45–60 °C35–50 °C40–50 °C−60 °C20–50 °C
Melting temperature 150–200 °C180–230 °C—60–65 °C120–180 °C
Young's modulus 1.5–4 GPa3–7 GPa1–2 GPa0.2–0.4 GPa0.3–1.5 GPa
Tensile strength 40–60 MPa50–100 MPa30–40 MPa20–40 MPa20–50 MPa
Elongation at break 1–10%1–10%1–10%300–1000%30–1000%
Degradation timeMonths, logarithmic scale. Ranges vary by composition and grade.

Scroll horizontally to explore the chart

Polylactide
PGA / PGLA
PLGA
PCL
PLCL
16122460
  • Polylactide
  • PGA / PGLA
  • PLGA
  • PCL
  • PLCL
Degradation time (months)
PolymerRange
Polylactide6 months to 5 years
PGA / PGLA2 to 12 months
PLGA1 to 6 months
PCL3 to 4 years
PLCL3 to 18 months
Polymer comparison: young's modulusPublished grade ranges in GPa. Compare one property at a time.

Scroll horizontally to explore the chart

Polylactide
PGA / PGLA
PLGA
PCL
PLCL
02468
  • Polylactide
  • PGA / PGLA
  • PLGA
  • PCL
  • PLCL
Polymer comparison: young's modulus (GPa)
PolymerRange
Polylactide1.5–4 GPa
PGA / PGLA3–7 GPa
PLGA1–2 GPa
PCL0.2–0.4 GPa
PLCL0.3–1.5 GPa
Questions and answers

Frequent questions about polymers.

No answer here? Write to us and a process engineer will reply on the substance of your task.

Ask a question
Which biodegradable medical polymers do you manufacture?
Polylactide (PLLA, PDLLA), poly(D,L-lactide-co-glycolide) (PLGA), polyglycolide (PGA) and poly(glycolide-co-L-lactide) (PGLA), poly(ɛ-caprolactone) (PCL) and poly(L-lactide-co-ɛ-caprolactone) (PLCL). All materials meet international quality standards for use in medicine and pharma.
What molecular weights are available?
From 1,000 to 500,000 Da (1 to 500 kDa). Molecular weight is selected for the task: low-molecular grades for drug formulations up to high-molecular grades for implants with long degradation times.
Which end groups can the polymer have?
Hydroxyl, carboxyl, ester and functional end groups. The end group type affects hydrolysis rate and the release kinetics of the active substance.
What degradation times do your polymers have?
From 1 month to 5 years depending on the material: PLGA 1–6 months, PGA and PGLA 2–12 months, PLCL 3–18 months, polylactide 6 months to 5 years, PCL 3–4 years. Degradation time is tuned by polymer composition and molecular weight.
Can you synthesize a polymer to our specification?
Yes. To the customer's specification we synthesize a polymer with a precisely defined composition, molecular weight, modified end groups and special architecture.
What feedstock is polylactide made from?
The feedstock for lactic acid production is annually renewable resources: corn and sugar cane.

Custom polymer synthesis

To the customer's specification we can synthesize a polymer with a precisely defined composition, molecular weight, modified end groups, special architecture and more.

Make a request